Featured
-
Hot-selling Electrophoresis Buffer Unit - UV Transilluminator WD-9403E – Liuyi
Specification Dimension 340 X 54 X 90mm Transmission UV Wavelength / Reflection UV Wavelength 254nm and 365nm Transmission Area 178×50mm UV Lamp Power 6W Weight 0.50kg Description WD-9403E is strong and compact with a viewing window. The glass plate of the viewing window is ultra-violet ray intercepting glass, it can protect your eyes. On the top of the apparatus, there is a cylinder for the connector and the filter that are for the digital camera to take the photos. T... -
OEM Factory for Power Supply For Hb Gel Electrophoresis Machine With Cell - Modular Dual Vertical System DYCZ – 25D – Liuyi
Specification Dimension (LxWxH) 175×163×165mm Gel Size (LxW) 75×83mm 95×83mm Comb 10 wells and 15 wells Comb Thickness 1.0mm and 1.5mm Number of Samples 40-60 Buffer Volume 1350 ml Weight 1.0kg Application For SDS – PAGE, Protein Electrophoresis. Feature • Casting gel in original position: Install gel casting chamber in the main body of electrophoresis apparatus directly, able to cast and run the gel at the same place; • Strong compatibility: ... -
Cheapest Price Page Electrophoresis - UV Transilluminator WD-9403B – Liuyi
Specification Dimension 390×316×121mm Transmission UV Wavelength 302nm Transmission Area 220×200mm UV Lamp Power 8W Weight 4.6kg Application Apply to observe gel for nucleic acid electrophoresis. Feature • UV protection cover with damping; • No dark box, easy to cut glue; • With the UV transmission function; • With metal edging. -
Good quality Use Of Gel Electrophoresis - Gel Imaging & Analysis System WD-9413B – Liuyi
Specification Dimension 458 x 445 x 775 mm Transmission UV Wavelength 302nm Reflection UV Wavelength 254nm and 365nm UV Light Transmission Area 252×252mm Visible Light Transmission Area 260×175mm Description WD-9413B Gel Documentation & Analysis System is strong and compact with a viewing window. The glass plate of the viewing window is ultraviolet ray intercepting glass, it can protect your eyes. On the top of the apparatus, there is a cylinder connectting the digital... -
-
Rapid Delivery for Gel Filtration Chromatography - Gel Imaging & Analysis System WD-9413A – Liuyi
Specification Dimension 458×445×755mm Transmission UV Wavelength 302nm Reflection UV Wavelength 254nm and 365nm UV Light Transmission Area 252×252mm Visible Light Transmission Area 260×175mm Application Apply to observe, take photos and analyse testing results of nucleic acid and protein electrophoresis. Feature • Dark chamber, no need dark room, can be used in all-weather; • Drawer-mode light box, convenient to use and avoid contamination; • Real time preview and auto-... -
Best Price for Electrophoretic Run - Blue LED Transilluminator WD-9403X – Liuyi
Specifications Dimension (LxWxH) 190x205x150mm Filter Size (LxWxH) 180X205X220mm Viewing Range (LxW) 150x150mm Max Cutting Gel Size 150x150mm Uniformity ≥90% Brightness Adjustment Knob Stepless Adjustment LED Lifetime (hours) ≥30000hs Emission Maxima (nm) 470nm Max Power 20W Input Voltage AC100-240V Description It is used for light source instrument for the observation and analysis of nucleic acids, proteins and other substances in the life science research field.... -
China New Product Integrated Gel Imaging System With Pc - Gel Imaging & Analysis System WD-9413C – Liuyi
Specification Dimension 388×375×753 mm Transmission UV Wavelength 302nm Reflection UV Wavelength 254nm and 365nm UV Light Transmission Area 252×252mm Visible Light Transmission Area 260×175mm Application Apply to observe, take photos and analyse testing results of nucleic acid and protein electrophoresis; Feature • Dark chamber design; no need dark room; can be used in all-weather; • Drawer-mode light box, convenient to use and avoid contamination; • Real time preview and a... -
Reasonable price Gel Electrophoresis Unit – Gel Imaging & Analysis System WD-9413B – Liuyi
Specification Dimension 458 x 445 x 775 mm Transmission UV Wavelength 302nm Reflection UV Wavelength 254nm and 365nm UV Light Transmission Area 252×252mm Visible Light Transmission Area 260×175mm Description WD-9413B Gel Documentation & Analysis System is strong and compact with a viewing window. The glass plate of the viewing window is ultraviolet ray intercepting glass, it can protect your eyes. On the top of the apparatus, there is a cylinder connectting the digital... -
OEM Factory for Power Supply For Hb Gel Electrophoresis Machine With Cell - Trans-Blotting Electrophoresis Cell DYCP – 40E – Liuyi
Specification Dimension (LxWxH) 270×250×104mm Blotting Area (LxW) 200×200mm Continuous Working Time ≥24 hours Weight 5.0kg Application For fast transferring the protein molecule from the gel to membrane like nitrocellulose membrane. Feature • Special design and selected material; • Semi-dry blotting, no need buffer solution; • Fast transfer speed and high transfer efficiency; • Safe plug technique, all the exposed parts are insulated; • The transfer bands are very... -
Hot-selling Electrophoresis Buffer Unit - Blue LED Transilluminator WD-9403X – Liuyi
Specifications Dimension (LxWxH) 190x205x150mm Filter Size (LxWxH) 180X205X220mm Viewing Range (LxW) 150x150mm Max Cutting Gel Size 150x150mm Uniformity ≥90% Brightness Adjustment Knob Stepless Adjustment LED Lifetime (hours) ≥30000hs Emission Maxima (nm) 470nm Max Power 20W Input Voltage AC100-240V Description It is used for light source instrument for the observation and analysis of nucleic acids, proteins and other substances in the life science research field.... -
Competitive Price for Electrophoresis Meaning - Blue LED Transilluminator WD-9403X – Liuyi
Specifications Dimension (LxWxH) 190x205x150mm Filter Size (LxWxH) 180X205X220mm Viewing Range (LxW) 150x150mm Max Cutting Gel Size 150x150mm Uniformity ≥90% Brightness Adjustment Knob Stepless Adjustment LED Lifetime (hours) ≥30000hs Emission Maxima (nm) 470nm Max Power 20W Input Voltage AC100-240V Description It is used for light source instrument for the observation and analysis of nucleic acids, proteins and other substances in the life science research field....