Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Responsible excellent and fantastic credit rating standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of "quality initial, buyer supreme" for Rapid Gel Electrophoresis Equipment, Gel Document Imaging System, Regulated Power Supply, We welcome new and previous clients from all walks of lifestyle to get in touch with us for long term business relationships and mutual accomplishment!
Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi Detail:

9413A

Specification

Dimension 458×445×755mm
Transmission UV Wavelength 302nm
Reflection UV Wavelength 254nm and 365nm
UV Light Transmission Area 252×252mm
Visible Light Transmission Area 260×175mm

36.GEL Imaging & Analysis System WD-9413A (5)
36.GEL Imaging & Analysis System WD-9413A (4)
36.GEL Imaging & Analysis System WD-9413A (3)
36.GEL Imaging & Analysis System WD-9413A (9)
36.GEL-Imaging-Analysis-System-WD-9413A-12
36.GEL-Imaging-Analysis-System-WD-9413A-11
36.GEL-Imaging-Analysis-System-WD-9413A-8
36.GEL-Imaging-Analysis-System-WD-9413A-1

Application

Apply to observe, take photos and analyse testing results of nucleic acid and protein electrophoresis.

Feature

• Dark chamber, no need dark room, can be used in all-weather;

• Drawer-mode light box, convenient to use and avoid contamination;

• Real time preview and auto-focus function;

• UV filter: Compatible with EB, Sybr,GoldView etc.fluorescent dye;

• Compatible with various image formats : tif ,jpg, bmp, gif, pcx.

36.GEL Imaging & Analysis System WD-9413A (6)
36.GEL Imaging & Analysis System WD-9413A (7)
GEL-Imaging-Analysis-System-WD-9413B-1
36.GEL-Imaging-Analysis-System-WD-9413A-12

System Configuration

• Imported high resolution digital camera;

• Imported professional analysis software;

• High configuration computer;

• High resolution colorful ink-jet printer.

Technical Specification

• Resolution: consistent with the camera;

• Effective pixels: 14.7 million pixels;

• Pixels density: 8 bit;

• Digital zoom: consistent with the camera;

• Optical zoom: consistent with the camera;

• Aperture range: F2.8/F4.5-F8.0;

• The speed of shutter:15-1/4000s;

• Macro automatic focus: consistent with the camera;

• Able to professionally analyse the result of 1D, 2D and AFLP experiments.

Powerful analysis software

• The image processing function;

• 1D analysis function;

• AFLP,RFLP,PCR homologous genetic clustering tree analysis;

• 2D analysis function;

• Clone technology;

• Colony and spot hybridization;

• Data results with MS Excel seamless connection;

• Software can be used for Win98/Me/2000/Windows7.

ae26939e xz


Product detail pictures:

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures


Related Product Guide:

In order to give you convenience and enlarge our business, we also have inspectors in QC Team and assure you our best service and product for Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi , The product will supply to all over the world, such as: Mecca, Nigeria, Southampton, As the world economic integration bringing challenges and opportunities to the xxx industry, our company , by carrying on our teamwork, quality first, innovation and mutual benefit, are confident enough to provide our clients sincerely with qualified products, competitive price and great service, and to build a brighter future under the spirit of higher, faster, stronger with our friends together by carrying on our discipline.
  • This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
    5 Stars By Doris from Bolivia - 2018.12.10 19:03
    The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Nicola from UK - 2018.12.11 14:13
    Write your message here and send it to us