We are going to make every single effort for being excellent and excellent, and accelerate our ways for standing while in the rank of international top-grade and high-tech enterprises for Native Page Electrophoresis, Gel Document Imaging System Economic Type For Lab, Electrophoresis In Chemistry, Our business has been devoting that "customer first" and committed to helping shoppers expand their small business, so that they become the Big Boss !
Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi Detail:

9413A

Specification

Dimension 458×445×755mm
Transmission UV Wavelength 302nm
Reflection UV Wavelength 254nm and 365nm
UV Light Transmission Area 252×252mm
Visible Light Transmission Area 260×175mm

36.GEL Imaging & Analysis System WD-9413A (5)
36.GEL Imaging & Analysis System WD-9413A (4)
36.GEL Imaging & Analysis System WD-9413A (3)
36.GEL Imaging & Analysis System WD-9413A (9)
36.GEL-Imaging-Analysis-System-WD-9413A-12
36.GEL-Imaging-Analysis-System-WD-9413A-11
36.GEL-Imaging-Analysis-System-WD-9413A-8
36.GEL-Imaging-Analysis-System-WD-9413A-1

Application

Apply to observe, take photos and analyse testing results of nucleic acid and protein electrophoresis.

Feature

• Dark chamber, no need dark room, can be used in all-weather;

• Drawer-mode light box, convenient to use and avoid contamination;

• Real time preview and auto-focus function;

• UV filter: Compatible with EB, Sybr,GoldView etc.fluorescent dye;

• Compatible with various image formats : tif ,jpg, bmp, gif, pcx.

36.GEL Imaging & Analysis System WD-9413A (6)
36.GEL Imaging & Analysis System WD-9413A (7)
GEL-Imaging-Analysis-System-WD-9413B-1
36.GEL-Imaging-Analysis-System-WD-9413A-12

System Configuration

• Imported high resolution digital camera;

• Imported professional analysis software;

• High configuration computer;

• High resolution colorful ink-jet printer.

Technical Specification

• Resolution: consistent with the camera;

• Effective pixels: 14.7 million pixels;

• Pixels density: 8 bit;

• Digital zoom: consistent with the camera;

• Optical zoom: consistent with the camera;

• Aperture range: F2.8/F4.5-F8.0;

• The speed of shutter:15-1/4000s;

• Macro automatic focus: consistent with the camera;

• Able to professionally analyse the result of 1D, 2D and AFLP experiments.

Powerful analysis software

• The image processing function;

• 1D analysis function;

• AFLP,RFLP,PCR homologous genetic clustering tree analysis;

• 2D analysis function;

• Clone technology;

• Colony and spot hybridization;

• Data results with MS Excel seamless connection;

• Software can be used for Win98/Me/2000/Windows7.

ae26939e xz


Product detail pictures:

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures

Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi detail pictures


Related Product Guide:

All we do is usually affiliated with our tenet " Buyer to start with, Belief to start with, devoting about the food packaging and environmental defense for Good User Reputation for Pcr Gel Electrophoresis - Gel Imaging & Analysis System WD-9413A – Liuyi , The product will supply to all over the world, such as: Greenland, Jordan, Yemen, Our company's main products are widely used all over the world; 80% of our products exported to the United States, Japan, Europe and other markets. All stuff sincerely welcome guests come to visit our factory.
  • In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
    5 Stars By Ivy from Argentina - 2018.05.13 17:00
    This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Lee from Guyana - 2018.09.21 11:01
    Write your message here and send it to us